Model 1511-LTC
The INCON Model 1511-LTC programmable process monitor is a sophisticated microprocessor-based panel instrument.
Applications
- The INCON Model 1511-LTC is ideal for use in applications that require accurate position measurement.
- Indicates tap position for load tap changers on transformers utilizing slidewire (resistive) transmitters
- Provides flexible, real-time, outputs to interface with SCADA, PLCs, and computers
- Provides visual and electrical indication of changes in tap position
- Performs absolute position feedback by providing positive confirmation that the LTC has moved to the required tap position as directed
- Programmable for uni-polar (0 to 32 taps) or bi-polar (-16 to +16 taps) applications
The Model 1511-LTC indicates the position of transformer load tap changers and can be used to perform a number of functions to help improve system operation.
- Analog output is unaffected by noisy or intermittent input signals
- Accepts a 0-24 VDC signal from a slidewire (resistive) transmitter
- Provides regulated 24 VDC slidewire power
- Mathematically averages 1000 input signal samples to accurately determine the actual input signal value
- Provides programmable segmented position indication
- Offers programmable limit outputs for alarm and control (optional)
Features
- Interfaces LTC position information to SCADA systems
- Extremely accurate signal conditioner
- Analog and/or digital output
- Large five-digit LED display
- Hard-wired security/ lockout feature
- Non-volatile storage of program parameters
- Easy, menu-driven, set up mode through its front panel
Specifications
| GENERAL |
| Input |
0-24 volts direct current |
| Resolution |
± 0.001% of full scale |
| Accuracy |
± 0.02% of full scale maximum
(.01% typical) |
| Temperature Drift |
± 0.01% per ° C |
| Operating Temperature |
0° to 55° C |
| Humidity |
10% - 90% non-condensing |
| Weight |
24 ounces |
| Dielectric test |
1000 VDC for 1 minute, line to any
other terminal |
| Voltage |
117/234 +/- 10%VAC |
| Frequency |
47 - 63 Hz |
| Load |
8 Watts maximum |
| Transmitter Power |
Internal 24VDC supply |
| DISPLAY |
| Type |
Five-digit LED |
| Digit Height |
0.56 inch (14.2 mm) |
| Viewing distance |
23 feet |
| Decimal point |
Field programmable |
| OPTIONAL
ANALOG OUTPUT |
| Outputs |
0-1mA, ±1mA, 0-2mA or 4-20mA
0-10 VDC or ±10 VDC |
| Compliance |
10 volts (0-1mA, ±1mA, 0-2mA)
(500 Ohms 4-20mA) 5 mA (0-10 VDC, ±10 VDC) |
| Non-Linearity |
+/- 0.1% of full scale |
| Resolution |
12 bits (+/- 0.025% of full scale) |
| OPTIONAL
HI/LO RELAYS |
| Contact Rating |
3A @ 125/250 VAC (resistive), 30 VDC |

Panel cut out: 1.653 (42mm) x 3.543 (90mm)
Panel thickness: 0.1 (2.7mm) to 0.19 (5.0mm)

Ordering Information
1511-LTC-q-r-t-u = options, see below
OPTIONS
| q= Analog Output: |
|
0 (0-1mA) |
|
4 (4-20mA) |
| |
|
1 (±1mA) |
|
10 (10VDC) |
| |
|
2 (0-2mA) |
|
11 (±10VDC) |
| r = Control: |
|
R (Hi/Low Relay Limits) |
| |
|
E (External Relays ) |
| t= Communications: |
|
PB
(Parallel Data) or S (RS-232),
or B (Multiplexed BCD) |
| |
|
| u= Line Voltage options: |
|
120 (120VAC) |
| |
240 (240VAC) |
PDF Downloads
Datasheet
Manual
Application Bulletin