Model 1250B
The Model 1250B provides highly accurate rotary position indication, with interfaces to SCADA, PLCs, and computers.
For many years this versatile instrument has been a Utility and Industrial standard for measuremen of:
- Head & Tailwater Level
- Stream or Pond Level
- Spillway Gate Position
- Governor Limit & Position
- Valve Position
- Fish Wier Position
This sophisticated instrument can help solve tough position measurement problems
- Non-Linear Conversion
- Multi-Turn Measurements
- Interfaces with PLCs and PC-Based SCADA Systems
- Programmable Alarm or Control Outputs
- MODBUS & ASCII Protocols
Features
- Absolute Position Feedback
- Proportional Analog Output Signal
- Programmable Hi/Lo Relay Limits
- RS-485 Multi-drop Communication
- RS-232 ASCII Serial Communication
- Programming via Serial Port
Benefits
- Highly Accurate
- Easy Automation Interface
- Proven Reliability
- Maintenance Free
- Retrofit to Older Systems
- Simple Programming
- Cost Effective
- Highly Visible LED Display
Specifications
| GENERAL |
| Input Signal |
Synchro (5 wire) 90V maximum |
| Resolution |
+/-0.001% of full scale or 6 arc minutes |
| Accuracy |
+/-0.02% of full scale maximum (.01%
typical) |
| Temperature Drift |
+/- 0.01 % per °C |
| Operating
Temp. |
0° to 55° C (standard) |
| Humidity |
10% - 90% non condensing |
| Weight |
24 ounces |
| Voltage |
117/234 +/- 10% |
| Frequency |
47 - 63 Hz |
| Load |
8 Watts, maximum |
| DISPLAY |
| Type |
5-digit LED |
| Digit Height |
0.56 inch (14.2 mm) |
| Viewing distance |
23 feet |
| Decimal point |
Field programmable (scaled modes only) |
| OPTIONAL
ANALOG OUTPUT |
| Outputs |
+/- 1 mA, 0-1mA, 0-2mA, 4-20mA (requires
external loop power) |
| Compliance |
10 Volts (0-1mA, +/- 1mA, 0-2mA) 500
Ohms (4-20mA) |
| Non-Linearity |
+/- 0.1% of full scale |
| Resolution |
12 bits (+/- 0.025% of full scale) |
| OPTIONAL
HI/LO RELAYS |
| Contact Rating |
3A @ 125/250 VAC (resistive),
30 VDC |

Panel cut out min.: 1.653 (42mm) x 3.543
(90mm)
(+2 / -0 mm)
Panel thickness: 0.1 (2.7mm) to 0.19 (5.0mm)
OPTIONAL ACCESSORIES
Model 1292 - Selsyn Synchro Transmitter
Model 1292K -Transmitter w/bracket
Model 1292KS - Transmitter w/bracket & surge protection
circuit
Model 1293 - Flexible coupling shaft
Model 1945 - 15 VDC Loop Power Supply (For 4-20mA Analog Output)
Ordering Information
| 1250B-U-W-X-Y-ZZZ = options, see below |
| OPTIONS |
| U = Output Options |
0 (0-1 mA) 2 (0-2 mA) 1 (±1 mA) 4 (4-20 mA) |
| W = Control |
R - Hi/Low Relay Limits |
| X = Input Option |
I - Input Isolation |
| Y = Comm. Options |
S - RS-232 M RS-485 MODBUS PB Parallel Data (BCD) |
| ZZZ = Line Voltage |
120 (120 VAC) or 240 (240 VAC) |
PDF Downloads
Datasheet
Manual
Application Bulletin